Journal of Pharmacy And Bioallied Sciences
Journal of Pharmacy And Bioallied Sciences Login  | Users Online: 751  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 
    Home | About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions | Online submission


ORIGINAL ARTICLE
Year : 2019  |  Volume : 11  |  Issue : 3  |  Page : 254-261

Determination of ethinyl estradiol and levonorgestrel in human plasma with prednisone as internal standard using ultra-performance liquid chromatography–tandem mass spectrometry


Faculty of Pharmacy, Universitas Indonesia, West Java, Indonesia

Correspondence Address:
Prof. Yahdiana Harahap
Faculty of Pharmacy, Universitas Indonesia, Depok 16424, West Java
Indonesia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jpbs.JPBS_68_19

Rights and Permissions

Objective: Ethinyl estradiol and levonorgestrel as a combination of oral contraceptive drugs have very low dosage levels; hence, a highly sensitive and selective method of using ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) is needed. Materials and Methods: This method was developed using prednisone as an internal standard, thus the purpose of this research was to get the optimum condition. The analytical method had been fully validated according to the European Medicines Agency guidelines, 2011. A reverse-phase chromatography separation was performed on ACQUITY UPLC ethylene bridged hybrid C18 column (1.7 μm, 2.1 × 50mm), eluted at a 0.3 mL/min flow rate under a gradient of mobile phase of 0.1% formic acid in water and acetonitrile within 5 min. Sample preparation used protein precipitation followed by liquid–liquid extraction. Quantification analysis was performed by a triple quadrupole mass spectrometry with electrospray ionization in positive-ion mode. The multiple reaction monitoring was set at m/z: 530.16 → 171.08 for ethinyl estradiol derivatized by dansyl chloride; m/z: 313.16 → 245.10 for levonorgestrel; and m/z: 359.10 → 147.04 for prednisone. Results: The validated method was accurate, precise, and sensitive with a lower limit of quantification at 5 and 100 pg/mL for ethinyl estradiol and levonorgestrel, respectively.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed443    
    Printed11    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal