ORIGINAL ARTICLE
Year : 2019  |  Volume : 11  |  Issue : 6  |  Page : 380-384  

The effect of surface treatments on the shear bond strength of acrylic resin denture base with different repair acrylic resin: An in vitro study


1 Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College For Women, Tiruchengode, India
2 Department of Prosthodontics, Private Clinic Practitioner, Kumbakonam, India
3 Department of Prosthodontics and Crown and Bridge, Rajah Muthiah Dental College and Hospital, Chidambaram, India
4 Department of Prosthodontics and Crown and Bridge, KSR Institute of Dental Science and Research, Tiruchengode, India
5 Department of Prosthodontics and Crown and Bridge, Sree Mookambika Institute of Dental Sciences, Kulasekharam, India
6 Department of Prosthodontics and Crown and Bridge, JKK Nataraja Dental College and Hospital, Komarapalayam, Tamil Nadu, India

Date of Web Publication28-May-2019

Correspondence Address:
Dr. P Arun Kumar
Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College for Women, Elayampalayam, Tiruchengode, Namakkal 637205, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JPBS.JPBS_40_19

Rights and Permissions
   Abstract 

Background: Fracture of the denture base is a common problem associated with dental prostheses. Fractured denture base surfaces treated with chemical agents and mechanical features have the potential for improved bond strength. Aim: The aim of this study was to evaluate the effect of surface treatment on the shear bond strength of heat-cured denture base with different repair acrylic resins. Materials and Methods: A total of 100 circular specimens (2-cm diameter × 3.3-mm thickness) were fabricated from heat-cured denture resins (DPI) according to the manufacturer’s instructions. The heat-cured denture base acrylic resin specimens were divided into two groups: In group 1, auto-polymerizing acrylic resin (DPI) was used as a repair resin, and in group 2, light-cured acrylic resin (VLC) was used as the repair resin. Further, the heat-cured denture base acrylic resin specimens were subdivided into five subgroups. The shear bond strength (in megapascal) was measured in a universal testing machine at a crosshead speed of 1mm/min. The results were subjected for statistical analysis. Result: Comparison of mean and standard deviation of shear bond strength between DPI and VLC group using one-way analysis of variance showed that the mean shear bond strength of DPI group is higher than that of VLC group. Conclusion: From the study, heat-cured denture base specimens repaired with auto-polymerizing repair resin showed higher mean shear bond strength than the visible light cure resin material.

Keywords: Auto-polymerizing resin, denture base, heat cure resin, visible light cure resin


How to cite this article:
Arun Kumar P, Iniyan K, Balasubramaniam R, Viswanathan M, Hines P A, Monnica V. The effect of surface treatments on the shear bond strength of acrylic resin denture base with different repair acrylic resin: An in vitro study. J Pharm Bioall Sci 2019;11, Suppl S2:380-4

How to cite this URL:
Arun Kumar P, Iniyan K, Balasubramaniam R, Viswanathan M, Hines P A, Monnica V. The effect of surface treatments on the shear bond strength of acrylic resin denture base with different repair acrylic resin: An in vitro study. J Pharm Bioall Sci [serial online] 2019 [cited 2019 Jun 18];11, Suppl S2:380-4. Available from: http://www.jpbsonline.org/text.asp?2019/11/6/380/258871




   Introduction Top


Denture bases made of acrylic resin are preferred because they chemically bond to denture tooth and are easier to adjust. Unfortunately, removable prosthesis of acrylic resin will fracture if dropped or stressed beyond their fractured strength. Many techniques and materials have been used to repair fractured denture. The ultimate aim is to restore the original strength of denture and to avoid further fracture. Denture repairs involve joining two parts of fractured denture with a denture repair material.

Repair of denture base is accomplished by an auto-polymerized repair acrylic resin and grinding the surface of the denture base. Attempts to improve bond strengths of denture base to the repair acrylic resin have involved mechanical and chemical treatments. Some authors have shown increased bonding strength by grinding a diatoric recess, which is a channel placed in the denture base to serve as a mechanical feature of retention. Recent studies tested an acrylic resin denture base surface treated with airborne-particle abrasion using 50-µm aluminum oxide particles. The study showed that airborne-particle abrasion increased bond strength and a larger particle size for air abrasion further improved the bond strength.[1] Priming of the denture base surface with monomer liquid during processing yielded significantly higher bond strength values than other surface treatments.[2],[3]

Polymethyl methacrylate (PMMA) is the most commonly used material for denture base fabrication. However, there have been reports of allergic response in patients sensitive to methyl methacrylate monomer.[4] Other organic solvents such as chloroform,[5] acetone,[6] ethylene chloride, and ethyl acetate have also been used for repair process. In some studies, organic solvents showed increase in bond strength between acrylic repair resin and denture base resin.[5],[7]

This study evaluated different surface treatment methods for denture base repair. The bond strength between the denture base and the auto-polymerizing repair acrylic resin and light-cured acrylic resin was tested. The purpose of this study was to determine the bond strength of an acrylic resin denture base repaired with auto-polymerizing repair acrylic resin and light-cured acrylic resin. This would lead to a recommendation for repair of acrylic resin denture base, and a method that would reduce the likelihood of further fracturing of the denture base.

[TAG:2]Materials and Methods[/TAG:2]

A total of 100 circular specimens (2-cm diameter × 3.3-mm thickness) were fabricated from heat-cured denture resins (DPI) according to the manufacturer’s instructions. The procedures for mixing and packing the resin into die stone molds were according to the conventional laboratory procedure for denture processing. The temperature was maintained at 74°C for 90 minutes, and then it was raised to 100°C for additional 30 minutes. The flasks were cooled to room temperature and the specimens were removed from the molds. Flash was carefully removed; to standardize, excess of 0.3mm was removed by grinding on 600-grit silicon carbide polishing paper to remove surface irregularities and compressed air was applied to remove excess material.[8],[9] Specimens were stored in distilled water at room temperature for 48 hours before testing, to simulate the effect of saliva.

After water storage, all specimens were ultrasonically cleaned with distilled water and dried with compressed air. The heat-cured denture base acrylic resin specimens were divided into two groups: in group 1, auto-polymerizing acrylic resin (DPI) was used as a repair resin, and in group 2 light-cured acrylic resin (VLC) was used as the repair resin.

Further the heat-cured denture base acrylic resin specimens were divided into five subgroups: for auto-polymerizing acrylic resin (DPI; n = 50), group A (n = 10), group B (n = 10), group C (n = 10), group D (n = 10), and group E (n = 10), and for light-cured acrylic resin (VLC; n = 50), group F (n = 10), group G (n = 10), group H (n = 10), group I (n = 10), and group J (n = 10). These are detailed as follows:



  1. Control group, which is untreated and no surface modification (group A [n = 10], group F [n = 10])


  2. 150-µm alumina air abrasion at a right angle to the surface from 5-mm distance for 10 seconds at an emission pressure of 0.48MPa using a delta blaster (group B [n = 10], group G [n = 10])


  3. Immersion in acetone (chemical etchant) for 30 seconds (group C [n = 10], group H [n = 10])


  4. Diatoric recess on ridge lap area of the denture base. Size of the recess was standardized by the 701 straight fissure carbide bur used with low-speed micro motor fixed in the dental surveyor mandrel (group D [n = 10], group I [n = 10]).


  5. Combination of 50-µm alumina air abrasion followed by the application of acetone for 30 seconds (group E [n = 10], group J [n = 10]).




All the specimens were mounted on flat surfaces facing up in the plastic holder (PVC pipe 25-mm diameter, 20-mm height) [Figure 1]. For auto-polymerizing acrylic resin (DPI), the specimens were mixed according to the manufacturer’s recommendation and placed into the PVC pipe, and excess material was removed from the top of the pipe. For light-cured acrylic resin (VLC), a brass ring (7-mm inner diameter and 2.5-mm height) [Figure 2] was used to add the repair resins, and the specimens were cured in the Triad curing unit with a stable platform as recommended by the manufacturer.
Figure 1: Prepared specimens

Click here to view
,
Figure 2: Specimens with brass mould

Click here to view


The shear bond strength (in megapascal) was measured in a universal testing machine [Figure 3] at a crosshead speed of 1mm/min. The results were subjected for statistical analysis.
Figure 3: Shear bond strength tested in universal testing machine

Click here to view



   Results Top


Comparison of mean and standard deviation of shear bond strength between DPI group and VLC group using one-way analysis of variance [Table 1] showed the mean shear bond strength of DPI group is higher than that of VLC group but the increase in mean value is statistically insignificant.
Table 1: Mean shear bond strength values for acrylic repair resins and different surface treatment

Click here to view


Further analysis with Tukey’s comparison procedure for multiple testing revealed that the mean shear bond strength was significantly different between all the groups. No significant differences (P > 0.05) were detected between the control group and specimens treated with acetone, diatoric recess, and combination of air abrasive followed by acetone according to the Tukey’s multiple comparison test. The shear bond strength of the mechanically treated samples was significantly higher than the control or chemically treated groups (P < 0.05).


   Discussion Top


In clinical situation, the fracture of heat cure denture bases is a common problem in both removable and complete dentures. Attempts to repair the fractured denture bases have been generally performed using auto-polymerizing resin with variable rate success. Recently, visible light cure and microwave cure denture base materials have also been used to repair the fractured denture bases. When repairing the denture base, it is important to know whether the bond strength between the denture base and the repair material is adequate, which is mandatory for the success of the repair base.

To improve the bond strength between the fractured denture base and the repair material, several mechanical and chemical surface treatments of the denture bases were tried. In this study, the shear bond strength of heat cure denture base with auto-polymerized and visible light cure resin is compared.

Shear strength is the maximum force that a material can tolerate before shear failure. Investigation of the shear bond strength of material interfaces is important. Many studies examined the transverse strengths of repaired specimens of acrylic resin.[10],[11] As the number of interface failures was more than cohesive failure, it is essential to evaluate the bonding failure of repair resin to base material by measuring shear bond strength. The shear bond test applies a shear load directly to the interface between repair material and denture base resin, which allows the results to be easily compared between materials.

The repair of a denture base can be performed using several materials, such as auto-polymerizing acrylic resin, heat-cure acrylic resin, visible light-polymerized resin, and microwave-polymerized acrylic resin. The choice of material depends on the working time, the strength to be obtained with the repair material, and the degree of dimensional stability maintained during and after repair.[12] Most debonded denture teeth repairs are made using a resin, which is generally simple and quick.[13] Specimens repaired with auto-polymerizing acrylic resin have approximately 60–65% of the original strength of the denture whereas the strength of heat-polymerized acrylic resin repairs ranges from 75% to 80% of the original bulk material. Repairs using heat-cure acrylic resins are seldom performed because they require a custom split cast gypsum mold, extended treatment time, and additional laboratory fee.[14] The patient must also be without the denture during the laboratory repair procedures. To overcome the limitations of heat-polymerized and auto-polymerizing acrylic resins, a visible light-polymerized system was introduced in 1984 and has been used in several applications including relining and repair of dentures.[7]

When a denture base is repaired, the bond strength between denture base resin and the repair material should be as strong as the parent denture base resin. The success of denture repair, however, depends on the adhesion between the repair material and the denture base.

Effect of mechanical treatment

Different opinions about the appropriate shape of the joint surfaces have been reported. Several studies have indicated different edge profiles, such as a butt joint,[15],[16] 45° bevel joint,[14],[17],[16] bevel joint rounded,[12],[18] and rabbet joint.

Mechanical surface treatment prior to denture base repair resulted in a significant improvement in the shear bond strength of the base materials. This finding is in agreement with a study by Minami et al.[1] He reported a significant increase in bond strength between the denture base resin and an auto-polymerizing resin; the mean bond strength of the specimen was 8.2MPa. In addition, Jagger et al.[19] found that a rough surface increases the friction between the denture base and the repair material, requiring more debonding force at the interface. Amarnath et al.[20] recommended sandblasting the acrylic denture base prior to repair and found that the bond strength of self-cure resin with denture base was 2.90MPa in control group and 7.56MPa in sandblast group.

Effect of chemical treatment

Chemical treatment with etchants on the surface causes crazing as well as the formation of numerous pits up to 2 μm in diameter. Wetting the repair surfaces with methyl methacrylate monomer has been used to soften the PMMA, which changes the morphology and chemical properties of the surface promoting adhesion. Vallittu et al.[22] found that when the monomer treatment was performed for 180 seconds, favorable results were attributed by the formation of new polymer chains between the heat-polymerized acrylic resin fracture surfaces. Similarly, Olvera and DeRijk[23] observed that monomer treatment for 4 minutes was the optimum treatment time for repairing denture base specimens. Alternatively, chloroform, acetone, and methylene chloride have been used as softening agents in several situations, including repair of denture bases.

Effect of water storage

It has been demonstrated that the strength of a denture repair may be time dependent. According to Harrison et al.,[24] auto-polymerizing acrylic resin repair is relatively weak at 1 hour after the laboratory procedure is completed. Paired specimens reached optimum strength after 1 day to 1 week of water immersion. Razavi et al.[7] found that the shear bond strength of visible light-polymerized resin significantly increased after 48 hours of water immersion. From the available literature, it can be assumed that repaired materials generally do not reach their optimum properties the following day, and for this reason, repaired dentures ideally should not be returned to the patient for at least 24 hours.[1]

The type of repair material exerts a considerable effect on the bond strength. In clinical situations, fractured denture base repaired with auto-polymerizing resin provide better bond strength, reduce the chair-side appointments, and enable faster repair. This study recommends mechanical treatment on the denture base prior to repair for optimum results.


   Conclusion Top


The success of PMMA denture repair depends on many variables such as combination of denture base resin and repair materials applied, repair surface design, repair surface treatments, and use of reinforcements. Few studies simulating clinical conditions of repair dentures have been performed.

From the study, heat cure denture base specimens repaired with auto-polymerizing repair resin showed higher mean shear bond strength than the visible light cure resin material. Also, mechanical surface treatment improved the bond strength than chemical surface treatment. So it is concluded that mechanically surface treated auto-polymerizing resin repair is more effective in the denture repairs. Future investigations should incorporate more closely simulated clinical conditions such as construction of denture-shaped base specimens.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Minami H, Suzuki S, Minesaki Y, Kurashige H, Tanaka T. In vitro evaluation of the influence of repairing condition of denture base resin on the bonding of autopolymerizing resins. J Prosthet Dent 2004;91:164-70.  Back to cited text no. 1
    
2.
Papazoglou E, Vasilas AI. Shear bond strengths for composite and autopolymerized acrylic resins bonded to acrylic resin denture teeth. J Prosthet Dent1999;82:573-8.  Back to cited text no. 2
    
3.
Rached RN, Del-Bel Cury AA. Heat-cured acrylic resin repaired with microwave-cured one: Bond strength and surface texture. J Oral Rehabil 2001;28:370-5.  Back to cited text no. 3
    
4.
Leggat PA, Kedjarune U. Toxicity of methyl methacrylate in dentistry. Int Dent J 2003;53:126-31.  Back to cited text no. 4
    
5.
Shen C, Colaizzi FA, Birns B. Strength of denture repairs as influenced by surface treatment. J Prosthet Dent 1984;52:844-8.  Back to cited text no. 5
    
6.
Kawara M, Carter JM, Ogle RE, Johnson RR. Bonding of plastic teeth to denture base resins. J Prosthet Dent 1991;66:566-71.  Back to cited text no. 6
    
7.
Razavi R, Khan Z, von Fraunhofer JA. The bond strength of a visible light-cured reline resin to acrylic resin denture base material. J Prosthet Dent 1990;63:485-7.  Back to cited text no. 7
    
8.
Al–Mallah AR. Effect of curing modes on the depth of cure of resin composite. Al–Rafidain Dent J 2007;7:195-200.  Back to cited text no. 8
    
9.
Geerts GA, Jooste CH. A comparison of the bond strengths of microwave- and water bath-cured denture material. J Prosthet Dent 1993;70:406-9.  Back to cited text no. 9
    
10.
Anusavice KJ. Phillips’ Science of Dental Materials. 11th ed. St. Louis, Missouri: Saunders-Elsevier; 2003. Chapter 4: Mechanical Properties of Dental Materials. p. 73-102.  Back to cited text no. 10
    
11.
Huang FM, Hu CC, Chang YC, Chou MY. The level of monomer release from acrylic denture base materials into water. Chin Dent J 2000;19:17-22.  Back to cited text no. 11
    
12.
Jassim RK, Radhi AAA. Evaluation the biological effect of two types of denture base materials reinforced with silanated glass fiber. J Bagh Coll Dentistry 2011;23:26-30.  Back to cited text no. 12
    
13.
Jain A, Ray S, Mitra R, Chopra SS. Light cure tip distance and shear bond strength: Does it have any clinical significance? J Ind Orthod Soc 2013;47:135-42.  Back to cited text no. 13
    
14.
Foo SH, Lindquist TJ, Aquilino SA, Schneider RL, Williamson DL, Boyer DB. Effect of polyaramid fiber reinforcement on the strength of 3 denture base polymethyl methacrylate resins. J Prosthodont 2001;10:148-53.  Back to cited text no. 14
    
15.
Polyzois GL, Tarantili PA, Frangou MJ, Andreopoulos AG. Fracture force, deflection at fracture, and toughness of repaired denture resin subjected to microwave polymerization or reinforced with wire or glass fiber. J Prosthet Dent 2001;86:613-9.  Back to cited text no. 15
    
16.
Ward JE, Moon PC, Levine RA, Behrendt CL. Effect of repair surface design, repair material, and processing method on the transverse strength of repaired acrylic denture resin. J Prosthet Dent 1992;67:815-20.  Back to cited text no. 16
    
17.
Nagai E, Otani K, Satoh Y, Suzuki S. Repair of denture base resin using woven metal and glass fiber: Effect of methylene chloride pretreatment. J Prosthet Dent 2001;85:496-500.  Back to cited text no. 17
    
18.
Tandon R, Gupta S, Agarwal SK. Denture base materials: From past to future. Ind J Dent Sci 2010;2:33-9.  Back to cited text no. 18
    
19.
Jagger RG, al-Athel MS, Jagger DC, Vowles RW. Some variables influencing the bond strength between PMMA and a silicone denture lining material. Int J Prosthodont 2002;15:55-8.  Back to cited text no. 19
    
20.
Amarnath GS, Indra Kumar HS, Muddugangadhar BC. Bond strength and tensile strength of surface treated resin teeth with microwave cured and heat cured acrylic resin denture base: An in-vitro study. Int J Clin Dent Sci 2011;2:27-32.  Back to cited text no. 20
    
21.
Shimizu H, Kurtz KS, Yoshinaga M, Takahashi Y, Habu T. Effect of surface preparation on the repair strength of denturte base resin. Int Chin Dent 2002;2:126-33.  Back to cited text no. 21
    
22.
Vallittu PK, Lasssila VP, Lappalainen R. Wetting the repair surface with methyl methacrylate affects the transeverse strength of repaired heat-polymerized resin. J Prosthet Dent 1994;72:639-43.  Back to cited text no. 22
    
23.
Olvera N, deRijk WG. Effect of surface treatments on the repair strength of a light-activated denture repair resin using censored data. Dent Mater 1994;10:122-7.  Back to cited text no. 23
    
24.
Harrison A, Belton EL, Meades K. Do self-curing acrylic resin repairs gain strength with age? J Dent 1977;5:334-8.  Back to cited text no. 24
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Materialsand Methods
   Results
   Discussion
   Conclusion
    References