Journal of Pharmacy And Bioallied Sciences
Journal of Pharmacy And Bioallied Sciences Login  | Users Online: 1694  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 
    Home | About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions | Online submission


ORIGINAL ARTICLE
Year : 2021  |  Volume : 13  |  Issue : 5  |  Page : 297-300

Assessment of the effect of bone density on implant stability: A clinical study


1 Department of Prosthodontics, Care Dental College, Guntur, Andhra Pradesh, India
2 Department of Prosthodontics, SIBAR Institute of Dental Sciences, Guntur, Andhra Pradesh, India
3 Department of Prosthodontics, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
4 Dr. Jagga Rao Konathala, MDS, Prosthodontics, Private Practitioner, Hyderabad, Telangana, India

Correspondence Address:
Raghunadh Sreerama
Department of Prosthodontics, Care Dental College, Guntur, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jpbs.JPBS_794_20

Rights and Permissions

Background: In this study, we determined the effect of bone density on implant stability. Methodology: Two hundred and sixty dental implant sites in 128 patients were assessed for resonance frequency analysis (RFA) following implant insertion, at 6 months and 12 months. The implant stability quotient (ISQ) was determined. Results: The mean ± standard deviation bone density in anterior mandible was 862.8 ± 203.4 Hounsfield units (HU), in posterior mandible was 528.4 ± 115.6 HU, in anterior maxilla was 594.2 ± 95.2 HU, and in posterior maxilla was 438.1 ± 110.2 HU. The mean insertion torque in successful implants was 38.2 ± 7.1 Ncm and in failed implants was 22.4 ± 4.2 Ncm. The mean RFA value in successful implants was 65.4 ± 5.8 and in failed implants was 45.8 ± 4.1 ISQ. A statistically significant (P < 0.05) difference was obtained. Conclusion: Within the limitation of the study, we observed that successful implants exhibited higher RFA and insertion torque and were higher into failed implants suggesting a correlation of bone quality and implant stability parameters.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

suppl
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed402    
    Printed12    
    Emailed0    
    PDF Downloaded29    
    Comments [Add]    

Recommend this journal