Journal of Pharmacy And Bioallied Sciences
Journal of Pharmacy And Bioallied Sciences Login  | Users Online: 1696  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 
    Home | About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions | Online submission




 
 Table of Contents  
ORIGINAL ARTICLE
Year : 2021  |  Volume : 13  |  Issue : 5  |  Page : 484-491  

Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study


1 Department of Preventive Dentistry, College of Dentistry in Alrass, Qassim University, Saudi Arabia
2 Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Qassim University, Saudi Arabia
3 Department of Conservative Dental Sciences, College of Dentistry, Qassim University, Saudi Arabia
4 Consulting Prosthodontist, Karnataka, India
5 Department of Prosthodontics. College of Dentistry in Alrass, Qassim University, Saudi Arabia

Date of Submission09-Dec-2020
Date of Decision15-Dec-2020
Date of Acceptance15-Dec-2020
Date of Web Publication05-Jun-2021

Correspondence Address:
Arshad Jamal Sayed
College of Dentistry in Alrass, Qassim University
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jpbs.JPBS_818_20

Rights and Permissions
   Abstract 


Aim: The purpose of this in vitro study was to investigate the influence of length and width of implant on primary stability in immediate implants in mandibular first molar. Materials and Methods: The study was carried out on 40 cone-beam computed tomography scans selected with defined inclusion and exclusion criteria. According to the diameter and length of implants, they were divided into nine groups (G1 to G9). The virtual implants of different diameters and length were placed in mandibular first molar and measurements were done for peri-implant horizontal and vertical gap defect, peri-implant interradicular bone support and apical bone support for all the groups. Results: The study groups Diameter, (D-7 mm) showed least horizontal gap defect (Buccal-1.30 ± 0.56 mm, lingual-1.30 ± 0.56 mm, mesial-1.20 ± 0.51 mm, and distal-1.05 ± 0.59 mm) as compared to regular implant diameter (D-4.7) groups (Buccal-2.35 ± 0.483 mm, lingual-2.10 mm ± 0.44 mm, mesial-2.30 ± 0.64 mm, and distal-2.25 ± 0.43 mm). The unsupported Vertical implant gap defect at the coronal part of the socket was 2.80 mm ± 0.83 mm for all groups in both horizontal and vertical direction. The vertical peri-implant interradicular bone support showed increased bone support with increase in implant length (L). The buccal and lingual inter-radicular bone-support was least for Length (L-8.5 mm), moderate for L-11.5 mm, and highest for L-13.5 mm groups, respectively. The mesial inter-radicular bone support was least for G4G7, moderate for G1G2G5G8, and maximum for G3G6G9 groups. Similarly, the distal inter-radicular bone support was least for G4G7, moderate for G1G5G8, and maximum for G2G3G6G9 groups, respectively. There was no apical bone support in L-8.5 mm group as the tip of implant was 3.5–4 mm within the socket tip. Whereas, L-11.5 mm had decent (0.9–1 mm) and L-13.5 mm had Good (1.35–1.95 mm) apical bone support as the implant tip was beyond the socket tip. Conclusion: All the groups showed good interradicular bone support on buccal and lingual surfaces. Regular width implants with longer length showed satisfactory interradicular bone support on mesial and distal surfaces. Longer implants showed good apical bone support in all the four surfaces and hence good apical primary stability expected.

Keywords: Bone support, gap defects, immediate molar implants, implant length and diameter, inter-radicular bone, primary stability


How to cite this article:
Sayed AJ, Shaikh SS, Shaikh SY, Hussain MA, Tareen SU, Awinashe V. Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study. J Pharm Bioall Sci 2021;13, Suppl S1:484-91

How to cite this URL:
Sayed AJ, Shaikh SS, Shaikh SY, Hussain MA, Tareen SU, Awinashe V. Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study. J Pharm Bioall Sci [serial online] 2021 [cited 2021 Dec 7];13, Suppl S1:484-91. Available from: https://www.jpbsonline.org/text.asp?2021/13/5/484/317706




   Introduction Top


The use of dental implants in restoring missing teeth has been increasingly accepted as a standard dental treatment. Literature provides insertion of implants into freshly extracted sockets with success. Primary implant stability is considered as a fundamental prerequisite for successful osseointegration.[1] In postextraction sites, the anatomical morphology influences primary stability and osseointegration.[2] Factors such as bone quantity, quality, the surgical technique of implant placement, and geometrical factors of the implant including shape, length, and diameter have a definite influence on the primary stability of the implant.[3] Immediate implants placed in the anterior region are more stable than those in the posterior region as, molar teeth being multi-rooted and socket sizes exceed that of most current implant diameters; therefore, it is difficult to estimate the optimal primary stability in the posterior mandible.[4]

Literature reveals cumulative survival rates ranging from 93.9% to 99% for immediate placement of implants in molar areas as compared to those placed in healed sites.[5],[6] Martinez et al. reported that the survival rate of implants in posterior mandible is much lower than anterior mandible due to poor quality of bone.[7] In mandibular molar teeth, where interradicular bone is insufficient in providing good primary stability, wider diameter implants may be preferred that can engage the perimeter wall of the molar sockets.[2],[8]

Consequently, immediate implants in the posterior region have been somehow a challenge to implantologists. Preservation and skillful engagement of the interseptal/interradicular bone is the cornerstone for the initial stability. A major disadvantage in cases of immediate implants is likely the mismatch, resulting due to the implant size and the socket wall; therefore, a potential gap exists after placement due to the irregularity in the root socket diameter and shape. De Angelis et al. advocated use of bovine inorganic bone substitute if the marginal gap was >2 mm.[9] However, Ferrus et al. concluded that this marginal gap eventually heals with formation of new bony tissue, thereby resolving the defect.[10] Literature does not provide with enough evidence to support or refute favoring augmentation procedures in case implants placed immediately into fresh extracted sockets and also superiority of one augmentation techniques over others.[11]

Increasing the length of implant plays a vital role to reduce the bone stress and enhancing the stability of implant.[3] Increasing implant diameter and also the length ensures a definite reduction in crestal strains and stress, however implant diameter has a significance effect as compared with increase in length in relieving the stress and strain concentration.[12] Some authors[7],[13] have reported that implant stability has no correlation with implant length, but diameter was considered as a determinant factor. Increasing the implant diameter will capitalize the buccal and lingual cortical plate engagement and hence better stability.[14] Modifications in surgical techniques such as drilling through the tooth into interradicular bone septa, use of longer and wider implants, and the vertical engagement of the apical threads of the implants, regenerative materials and bone grafts help in success of the Immediate Molar Implant (IMI).[15] The paucity of literature regarding the methods for measuring the primary stability of IMI to validate the effectiveness of variations in implant dimensions for the success rate. Hence, the purpose of this in vitro study was to investigate the influence of length and width of implant on primary stability in bone of posterior multi-rooted teeth (Mandibular 1st molar).

Cone-beam computed tomography (CBCT) provides numerous advantages in clinical decision-making and is considered a well-established virtual simulation tool facilitating extensively as diagnostic and treatment planning particularly in implant dentistry.[16],[17]

This study is based on virtual implant placement to quantitatively evaluate stability achieved by different length and diameter of implants with amount of bone engagement by means of CBCT.


   Materials and Methods Top


This cross-sectional descriptive study received Institutional ethics committee approval. A total of 40 CBCT Digital Imaging and Communications in Medicine (DICOM) files that had already been made for diagnostic purposes were obtained. The inclusion criteria were: (1) Presence of completely erupted mandibular molar teeth (except third molar), (2) closed root apices with root length of 10 mm and inter root apex distance from 3 to 7 mm, (3) presence of opposing maxillary teeth, (4) each tooth should be normally positioned (the imaginary line connecting the cusp tip of canines, central grooves of premolars, and molars was generally smooth.[18] The exclusion criteria were: (1) Crowding or ectopic eruption of mandibular teeth, (2) presence of periapical radiolucency, periodontal pathology or any other pathology, (3) partial or unclear images.

Imaging protocol

All the scans were taken on Galileo's comfort (Sirona Dental Systems GmbH, Bensheim, Germany) in high definition mode and with metal artifact reduction software. The scan parameters were 85KvP, 21 mAs, and 14 s scan time with FOV of 15 cm × 15 cm × 15 cm and voxel size 0.3 mm3.

Virtual implant placement

The DICOM files were imported in implant planning software (BlueSky bio, blue sky plan. com, IL, United States). The virtual implant was placed in mandibular first molar aligning mesio distally along the long axis of the crown of mandibular first molar and at 2 mm from the adjacent tooth roots. Apico coronally the coronal platform of the implant was at the crestal level. Bucco lingually, the implant was aligned along the imaginary line passing through the central fossae of the adjacent teeth. The mesiodistal and buccolingual angulation of the implant depended on the long axis of the opposing maxillary tooth and the curvature of mandibular occlusal plane. The functional cusp of the opposing teeth was in the center of the implant. Subsequent implants were superimposed on the first one by utilizing the duplicate tool and then changing the dimensions hence maintaining the placement protocol [Figure 1]a and [Figure 1]b.
Figure 1: Cone-beam computed tomography images for virtual implant placement protocol in mandibular first molar tooth with various dimensions (G1 to G9) as per surgical guidelines. (a) Sagittal section. (b) Cross section

Click here to view


Different combinations of implant width and height were selected and accordingly groups were made [Table 1].
Table 1: Different groups with the implant diameter and height

Click here to view


Measurements

The DICOM file was opened in the software and the image of mandibular first molar aligned in all the three sections. Interradicular and apical bone measurements were done in the sagittal and cross section views for all groups of implants [Table 2] and [Figure 2]a, [Figure 2]b and [Figure 3]a, [Figure 3]b.
Table 2: Measured parameters of mandibular 1st molar (1 M) sites

Click here to view
Figure 2: Schematic picture showing gap defects and interradicular bone support around immediate mandibular first molar implants. (a) MGDh: Mesial horizontal gap defect, DGDh: Distal Horizontal, gap defect L1: Vertical gap defect (mesial, distal), IRBm: Mesial interradicular bone support, IRBd: Distal interradicular bone support (b) BGDh: Buccal horizontal gap defect, LGDh: Lingual horizontal, gap defect V4: Vertical gap defect (4 walls – mesial, distal, buccal, and lingual), IRBb: Buccal interradicular bone support, IRBl: Lingual interradicular bone support, BCP: Buccal cortical plate, LCP: Lingual cortical plate

Click here to view
Figure 3: Showing virtual implant with coronal gap defects around implant and Interradicular bone support. (a) Sagittal section. (b) Cross sectio

Click here to view


The measurement of the integrated routing and bridging (IRB) was converted into percentile by using the percentile function in excel.

The qualified observers, for bone measurements, were blinded to the aim of the study. There was a calibration session before the initiation of image evaluation and a training session. In disagreement, the cases were discussed until consensus was reached. For inter- and intra-observer reliability, 25% (10 CBCT images) of the sample were randomly selected and analyzed again by 2 observers using Intraclass Correlation Coefficient.

Statistical analysis

All the parameter data were entered into SPSS v. 11.5 software (SPSS Inc., Chicago, IL, USA) for descriptive statistics for mean and standard deviation analysis. One-way analysis of variance followed by Post hoc Tukey test was done to comparative analysis between the groups and the P < 0.05 were considered statistically significant.


   Results Top


Variation in implant diameter and associated peri-implant bone defect (horizontal and vertical) measurements

The measurements [Table 3] of study groups G1G2G3 (Diameter [D]-4.7 mm) showed buccal peri-implant gap defect of 2.35 mm ± 0.483 mm, G4G5G6 (D-5.8 mm) was 2.00 mm ± 0.453 mm, and G7G8G9 (D-7 mm) was 1.30 mm ± 0.56 mm. This was due to the variation in the implant diameter. Similarly, the peri-implant defects on the lingual side for G1G2G3 (D-4.7 mm) was 2.10 mm ± 0.44 mm, for G4G5G6 (D-5.8 mm) was 1.70 mm ± 0.46 mm, and for G7G8G9 (D-7 mm) was 1.30 mm ± 0.56 mm. Mesial peri-implant defect for 4.7 mm diameter implants (G1G2G3) was 2.30 mm ± 0.64 mm, for 5.8 mm (G4G5G6) was 1.50 mm ± 0.59 mm, and for 7 mm (G7G8G9) was 1.20 mm ± 0.51 mm.
Table 3: Bone support and gap defect measurements (horizontal and vertical) for the virtual peri-implant parameters, mean with standard deviation values (in mm):

Click here to view


Distal peri-implant gap defect for 4.7 mm diameter implants (G1G2G3) was 2.25 mm ± 0.43 mm, for 5.8 mm (G4G5G6) was 1.55 mm ± 0.50 mm, and for 7 mm (G7G8G9) was 1.05 mm ± 0.59 mm. There was statistically significant difference (P ≥ 0.05) between the ultra-wide (G7G8G9) and the other groups for buccal, lingual, mesial, and distal gap defect measurements.

Vertical component of implant gap defect at the coronal part of the socket (L1-shoulder to inter-radicular septa) was 2.80 mm ± 0.83 mm for all groups in vertical direction. There was no statistical significance between these study groups.

Variation in Implant length and associated peri-implant interradicular bone support measurements

The measurements [Table 4] of length variation in implant study groups showed percentage wise increase of buccal bone-support (73.25% ± 11.11%, 80.30% ± 8.34%, and 83.35% ± 7.04%) for L-8.5 mm (G1G4G7), L-11.5 mm (G2G5G8), and L-13.5 mm (G3G6G9) groups respectively.
Table 4: Measurements of peri-implant vertical interradicular bone support measurements (mean with standard deviation values):

Click here to view


Similarly, the lingual bone support was also increased with increase in implant length (73.35% ± 10.32%, 80.25% ± 7.63%, and 83.20% ± 6.32%) for L-8.5 mm (G1G4G7), L-11.5 mm (G2G5G8), and L-13.5 mm (G3G6G9), respectively. Significant Statistical difference (P ≥ 0.05) was seen between L-8.5 mm (G1G4G7) and L-13.5 mm (G3G6G9) for both buccal and lingual bone support.

The mesial inter-radicular bone support varied with change in diameter and length of the implant. The percentage of bone support showed least for G4G7 (0.35% ± 0.97%, 0.15% ± 0.62%), moderate for G1G2G5G8 (1.85% ± 6.58%, 6.13% ± 13.96%, 2.95% ± 8.37%, 3.70% ± 7.89%) and maximum for G3G6G9 (16.35% ± 16.03%, 10.05% ± 12.01%, 9.30 ± 9.53), respectively. Similarly, the distal inter-radicular bone support also varied with change in diameter and length of the implant with percentage of bone support least for G4G7, (3.55% ± 7.61%, 0.40% ± 1.29%), moderate for G1G5G8 (7.80% ± 13.86%, 9.55% ± 16.46%, 8.80% ± 12.26%), and maximum for G2G3G6G9 (16.53% ± 20.88%, 28.28% ± 26.88%, 22.83% ± 24.89%, 16.70% ± 13.62%), respectively.

Significant difference was seen with increase in diameter and length of the implant for mesial and distal bone support.

Measurements' from the tip end of the implant to the socket tip of root for apical bone support

G1G4G7 Short length implant groups, (L-8.5 mm) was 3.5–4 mm within the socket tip indicating no apical bone support. G2G5G8 implant groups (L-11.5 mm) was 0.9–1 mm within socket tip indicating implant tip just engaging the apical bone support. G3G6G9 implant groups (L-13.5 mm) was 1.35–1.95 mm beyond the socket tip indicating good apical bone support.


   Discussion Top


The present study carried out to analyze the alteration in diameter and length of implants for primary stability of IMI with respect to change in peri-implant gap defects and interradicular bone support. Some studies have concluded that length and diameter of implant do not alter the stability of implant if the implants are placed in high quality bone.[19],[20]

This concept may be true for implants placed in healed socket or delayed placement. However, in cases of bone with low quality or implant insertion immediately after extraction (IMI) would be a debatable issue since the bone quantity and quality is not optimum.

Peri-implant gap defect

The present study reports showed a significant reduction in peri-implant gap defect in buccal, lingual, mesial and distal surfaces in ultra-wide (7 mm) group as compared with regular diameter (D-4.8 mm) groups. Our results suggest that wider the implants placed in IMI sockets, lesser the peri-implant gap defect (1.05–1.20 mm) and hence, bone augmentation is not always needed in wider or ultra-wide IMI. These findings are similar with other reports, where if the gap defect is <2 mm, natural bone healing can be predicted without the necessity for augmentation techniques.[21],[22] However, if the gap defect is more, then Guided bone or soft-tissue augmentation are indicated.[23],[24] In conclusion if there is sufficient or larger molar sockets, then larger diameter or wider molar implants are to be preferred to get benefits of better primary stability and faster healing without grafting interventions.

In our study, the vertical component of gap defect (L1) from crest to furcation was 2.80 ± 0.83 mm in all groups on all four peri-implant surfaces. The percentile defect varied depending on the length of the implant and as well the width of the interradicular bone, that is, longer the implants chosen, the vertical gap defect percentile decreased and hence more stability for implants.[25]

Inter-radicular bone support

Our study showed higher inter-radicular bone support for longer (13.5 mm) implant groups (G3, G6, and G9) as compared to shorter (8.5 mm) implant groups (G1, G4, and G7). For both surfaces (buccal, lingual), the inter-radicular bone support was identical (80%–83%) in all groups and did not vary with the alteration in diameter of the implant. Whereas for remaining two surfaces (mesial, lingual), the bone support varied significantly with alteration in diameter and length of the implants [Table 4]. Shorter and wider implant groups (L-8.5 mm and D-5.7 mm) showed least inter-radicular bone support, longer and wider implants (L-13.5 mm and D-7 mm) showed moderate IRB support, whereas, longer and regular width implants (L-13.5 mm and D-4.7 mm) showed maximum IRB support. Reports suggests when the diameter and location are kept constant, the longer implants showed much higher success rate as compared to shorter.[26] If IRB in fresh extraction is intact with <2 mm gap defect in the socket, then the stability of implant will be favorable and the required healing period will be shorter (12–13 weeks) without any need for regenerative interventions.[27] Ostman et al. reported the use of 10–13 mm length implants resulted in satisfactory primary stability as compared to 15–18 mm length. They suggested, higher the length, more heat generated during drilling and hence low primary stability.[28] Whereas, other studies reported increased rate of failure for ultra-wide (D-6-9 mm) implants and suggested a minimum bone thickness of 1.8 mm will provide good success rate.[29],[30] As well, Bilhan et al. reported no significance difference in primary stability of implant for variation in implant diameter.[31]

These results suggest implants that are longer (11–13.5) and wider (5–7 mm) are more suitable for IMI. Ultra-wide (7–9 mm) implants may be preferred in selective cases of either very wide inter-radicular septum or in cases of compromised vertical height of bone to get higher primary stability.

Apical bone support

The apical bone support refers to the IRB and Interdental bone around implant, that is normally available if implant in beyond the apex and all four surfaces of implants are in contact with the alveolar bone.

In our study, reports showed tip of shorter (8.5 mm) implants (G1, G4, G7) were within the mesial and distal root socket tip, thus indicating only buccal and lingual wall was providing primary stability for these implants. The 11.5 mm length implants (G2, G5, G8), tip of the implant was either until the socket tip or 0.9–1 mm of apical bone support was available for implants. Whereas the longer (13.5 mm) implants (G3, G6, G9) were 1.35 mm to 1.95 mm apical to socket tip suggesting these implants had good apical bone or, four wall bone support in providing primary stability for IMI as compared with the other length groups. Our results are similar to the findings of other studies where implants with 40% shorter length decreased the implant anchorage by 50%[32] and as well the implant should be placed into a minimum of 3 mm of solid bone apical to the extraction site to gain good apical bone primary stability.[33],[34] Many reported short implants failed as compared to longer, as they provide small surface area and decreased crown-to-implant ratio.[35],[36] Increasing the implant length will help in increasing the stability due to increase in area of osseointegration and a decrease in stress at the crestal bone with minimum crestal bone resorption. In case of poor bone quality, longer implants impart better stability.[37],[38]


   Conclusion Top


Variations in length and diameter of implants for placement immediately after extraction plays a crucial role as it varies the gap defects around the coronal part of implants and IRB support at the apical region, which, may influence the primary stability and longevity of the implant. In the present study all the groups showed good interradicular bone support on buccal and lingual surfaces. Regular width implants with longer length showed satisfactory interradicular bone support on mesial and distal surfaces. Wider the implants there was no interradicular bone support in the proximal surfaces and hence less chances for additional primary stability for IMI. Longer the implants better the vertical bone support. Longer implants showed good apical bone support in all the four surfaces and hence good apical primary stability expected. Further long-term randomized control trials should be carried out to accept our findings.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Zhou Y, Jiang T, Qian M, Zhang X, Wang J, Shi B, et al. Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant. Biomaterials 2008;29:461-74.  Back to cited text no. 1
    
2.
Meijer HJ, Raghoebar GM. Immediate implant placement in molar extraction sites: A 1-year prospective case series pilot study. Int J Implant Dent 2020;6:3.  Back to cited text no. 2
    
3.
Kong L, Sun Y, Hu K, Li D, Hou R, Yang J, et al. Bivariate evaluation of cylinder implant diameter and length: A three-dimensional finite element analysis. J Prosthodont 2008;17:286-93.  Back to cited text no. 3
    
4.
Mesa F, Muñoz R, Noguerol B, de Dios Luna J, Galindo P, O'Valle F. Multivariate study of factors influencing primary dental implant stability. Clin Oral Implants Res 2008;19:196-200.  Back to cited text no. 4
    
5.
Crespi R, Capparè P, Gherlone E. Fresh-socket implants in periapical infected sites in humans. J Periodontol 2010;81:378-83.  Back to cited text no. 5
    
6.
Fugazzotto PA. Implant placement at the time of maxillary molar extraction: Treatment protocols and report of results. J Periodontol 2008;79:216-23.  Back to cited text no. 6
    
7.
Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res 2001;12:423-32.  Back to cited text no. 7
    
8.
Sayed AJ, Shaikh SS, Shaikh SY, Hussain MA. Inter radicular bone dimensions in primary stability of immediate molar implants – A cone beam computed tomography retrospective analysis. Saudi Dent J;2021;33:71.  Back to cited text no. 8
    
9.
De Angelis N, Sorrenti E, Modena C, Benedicenti S. Evaluation of primary stability of single implants placed in fresh extraction sockets: A clinical trial. Biotechnol Biotechnol Equip 2016;30:354-9.  Back to cited text no. 9
    
10.
Ferrus J, Cecchinato D, Pjetursson EB, Lang NP, Sanz M, Lindhe J. Factors influencing ridge alterations following immediate implant placement into extraction sockets. Clin Oral Implants Res 2010;21:22-9.  Back to cited text no. 10
    
11.
Esposito M, Grusovin MG, Polyzos IP, Felice P, Worthington HV. Timing of implant placement after tooth extraction: Immediate, immediate-delayed or delayed implants? A Cochrane systematic review. Eur J Oral Implantol 2010;3:189-205.  Back to cited text no. 11
    
12.
Ding X, Liao SH, Zhu XH, Zhang XH, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants. Clin Implant Dent Relat Res 2009;11:279-87.  Back to cited text no. 12
    
13.
Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study. Clin Implant Dent Relat Res 2002;4:128-32.  Back to cited text no. 13
    
14.
Lee JH, Frias V, Lee KW, Wright RF. Effect of implant size and shape on implant success rates: A literature review. J Prosthet Dent 2005;94:377-81.  Back to cited text no. 14
    
15.
Barone A, Toti P, Marconcini S, Derchi G, Saverio M, Covani U. Esthetic Outcome of Implants Placed in Fresh Extraction Sockets by Clinicians with or without Experience: A Medium-Term Retrospective Evaluation. Int J Oral Maxillofac Implants 2016;31:1397-406.  Back to cited text no. 15
    
16.
Bornstein MM, Horner K, Jacobs R. Use of cone beam computed tomography in implant dentistry: Current concepts, indications and limitations for clinical practice and research. Periodontol 2000 2017;73:51-72.  Back to cited text no. 16
    
17.
Shaikh SY, Shaikh SS. Direct linear measurement of root dentin thickness and dentin volume changes with post space preparation: A cone-beam computed tomography study. Contemp Clin Dent 2018;9:77-82.  Back to cited text no. 17
[PUBMED]  [Full text]  
18.
Wang TY, Kuo PJ, Fu E, Kuo HY, Nie-Shiuh Chang N, Fu MW, et al. Risks of angled implant placement on posterior mandible buccal/lingual plated perforation: A virtual immediate implant placement study using CBCT. J Dent Sci 2019;14:234-40.  Back to cited text no. 18
    
19.
Barikani H, Rashtak S, Akbari S, Badri S, Daneshparvar N, Rokn A. The effect of implant length and diameter on the primary stability in different bone types. J Dent (Tehran) 2013;10:449-55.  Back to cited text no. 19
    
20.
Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15:529-39.  Back to cited text no. 20
    
21.
McAllister BS, Haghighat K. Bone augmentation techniques. J Periodontol 2007;78:377-96.  Back to cited text no. 21
    
22.
Chen ST, Darby IB, Reynolds EC, Clement JG. Immediate implant placement postextraction without flap elevation. J Periodontol 2009;80:163-72.  Back to cited text no. 22
    
23.
Rominger JW, Triplett RG. The use of guided tissue regeneration to improve implant osseointegration. J Oral Maxillofac Surg 1994;52:106-12.  Back to cited text no. 23
    
24.
Schliephake H, Dard M, Planck H, Hierlemann H, Jakob A. Guided bone regeneration around endosseous implants using a resorbable membrane vs a PTFE membrane. Clin Oral Implants Res 2000;11:230-41.  Back to cited text no. 24
    
25.
Rosenbach D. Gap management around immediate implants: A review of the literature and its application in clinical practice. Dentaltown; Sep 2014;44-9.  Back to cited text no. 25
    
26.
Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery – Clinical, prospective, biomechanical, and imaging study. Bone 2005;37:776-80.  Back to cited text no. 26
    
27.
Zamad M, Zamad A, Daga A, Akhare P. Immediate placement of mandibular molar dental implants: Case reports. J Implant Adv Clin Dent 2015;7:11-9.  Back to cited text no. 27
    
28.
Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19:77-83.  Back to cited text no. 28
    
29.
Ormianer Z, Palti A, Demiralp B, Heller G, Lewinstein I, Khayat PG. Implant-supported first molar restorations: Correlation of finite element analysis with clinical outcomes. Int J Oral Maxillofac Implants 2012;27:e1-12.  Back to cited text no. 29
    
30.
Mordenfeld MH, Johansson A, Hedin M, Billström C, Fyrberg KA. A retrospective clinical study of wide-diameter implants used in posterior edentulous areas. Int J Oral Maxillofac Implants 2004;19:387-92.  Back to cited text no. 30
    
31.
Bilhan H, Geckili O, Mumcu E, Bozdag E, Sünbüloğlu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil 2010;37:900-7.  Back to cited text no. 31
    
32.
Ueno T, Yamada M, Hori N, Suzuki T, Ogawa T. Effect of ultraviolet photoactivation of titanium on osseointegration in a rat model. Int J Oral Maxillofac Implants 2010;25:287-94.  Back to cited text no. 32
    
33.
Esposito M, Grusovin MG, Willings M, Coulthard P, Worthington HV. The effectiveness of immediate, early, and conventional loading of dental implants: A Cochrane systematic review of randomized controlled clinical trials. Int J Oral Maxillofac Implants 2007;22:893-904.  Back to cited text no. 33
    
34.
Werbitt MJ, Goldberg PV. The immediate implant: Bone preservation and bone regeneration. Int J Periodontics Restorative Dent 1992;12:206-17.  Back to cited text no. 34
    
35.
Kotsovilis S, Fourmousis I, Karoussis IK, Bamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants. J Periodontol 2009;80:1700-18.  Back to cited text no. 35
    
36.
Kong L, Gu Z, Li T, Wu J, Hu K, Liu Y, et al. Biomechanical optimization of implant diameter and length for immediate loading: A nonlinear finite element analysis. Int J Prosthodont 2009;22:607-15.  Back to cited text no. 36
    
37.
Bataineh AB, Al-Dakes AM. The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis. J Clin Exp Dent 2017;9:e1-6.  Back to cited text no. 37
    
38.
Silva R, Villalón P, Cáceres F. Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study. J Oral Biol Craniofac Res 2020;10:603-7.  Back to cited text no. 38
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed410    
    Printed8    
    Emailed0    
    PDF Downloaded33    
    Comments [Add]    

Recommend this journal