|
|
 |
ORIGINAL ARTICLE |
|
Year : 2021 | Volume
: 13
| Issue : 6 | Page : 1345-1349 |
|
|
Prevalence of titanium hypersensitivity in patients with titanium implants: A systematic review and meta-analysis
Rajsandeep Singh1, Gurvanit Lehl2, Arshad Bin Hussain3, Tejal Nivrutti Abhang4, Manisha Mangesh Kulkarni5, Mohamed Fadul A Elagib6, Rahul V C Tiwari7
1 Department of Prosthodontics, Government Medical College and Hospital, Chandigarh, India 2 Department of Pedodontics, Government Medical College and Hospital, Chandigarh, India 3 Department of Public Health Dentistry, Regional Dental College, Guwahati, Assam, India 4 Department of Prosthodontics, Vasantdada Patil Dental College and Hospital, Sangli, India 5 Department of Prosthodontics, YCMM RDF's Dental College, Ahmednagar, Maharashtra, India 6 Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia 7 Department of OMFS, Narsinbhai Patel Dental College and Hospital, Sankalchand Patel University, Visnagar, Gujarat, India
Date of Submission | 11-Mar-2021 |
Date of Decision | 10-Apr-2021 |
Date of Acceptance | 09-May-2021 |
Date of Web Publication | 10-Nov-2021 |
Correspondence Address: Rahul V C Tiwari Department of OMFS, Narsinbhai Patel Dental College and Hospital, Sankalchand Patel University, Visnagar - 384 315, Gujarat India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/jpbs.jpbs_159_21
Abstract | | |
Background: With increase in exposure to titanium in daily life and its use in medical procedures, there is a greater chance for developing titanium hypersensitivity. Our aim and objective is to examine whether patient patients with titanium implants had a greater incidence of titanium hypersensitivity or not. Titanium is widely considered to have good biocompatibility. A passivating surface layer of TiO2 is formed when exposed to air which gives it good corrosion resistance. These properties along with its high strength, lightweight, and improvements in smelting technologies have led to its widespread use as an intraosseous and periosteal implant in dentistry and orthopedics. Materials and Methods: Only case–control studies were used for the meta-analysis. Studies with a sample size of <5 were excluded. Cutaneous and epicutaneous tests were used in the study. Results: Three studies met the inclusion criteria. Titanium hypersensitivity is more prevalent in patients with titanium implants. Conclusions: It is also used in a variety of medical devices such as pacemakers and insulin pumps. Moreover, our external exposure to titanium is increasing. It is used in aerospace, chemical, and automobile industries. It is also used in jewelry, home furnishings, and in making sports and marine equipment. Titanium implants increase the possibility of developing titanium hypersensitivity, and thus, it should be considered as a major factor in unexplained implant failure where other causes have been excluded.
Keywords: Dental implants, hypersensitivity, metallurgy, titanium
How to cite this article: Singh R, Lehl G, Hussain AB, Abhang TN, Kulkarni MM, Elagib MF, Tiwari RV. Prevalence of titanium hypersensitivity in patients with titanium implants: A systematic review and meta-analysis. J Pharm Bioall Sci 2021;13, Suppl S2:1345-9 |
How to cite this URL: Singh R, Lehl G, Hussain AB, Abhang TN, Kulkarni MM, Elagib MF, Tiwari RV. Prevalence of titanium hypersensitivity in patients with titanium implants: A systematic review and meta-analysis. J Pharm Bioall Sci [serial online] 2021 [cited 2022 Aug 16];13, Suppl S2:1345-9. Available from: https://www.jpbsonline.org/text.asp?2021/13/6/1345/329989 |
Introduction | |  |
Titanium is mostly used as titanium dioxide. It is used as a whitening agent in paints, sunscreens, and as a filler in pharmaceutical and food industries. This widespread can cause an increased number of patients to be sensitized to titanium. Hypersensitivity is an exaggerated immune response to a known antigen. Metal ions act as haptens and combine with proteins to trigger a cell-mediated immune response. They can also cause the degranulation of mast cells and basophils. They can thus cause Type I and Type IV hypersensitization reactions.[1] Titanium ions accumulate in the peri-implant area, regional lymph nodes, and the lungs.[2],[3],[4] Titanium particles can be found in macrophage lysosomes[5],[6] and can cause Type IV hypersensitivity reactions. Cases of titanium allergy where the main signs and symptoms are urticaria, edema, eczema, and pruritus which may be localized or generalized[7],[8],[9] have been reported in the literature. In some cases, more serious problems such as eczema,[9] slow healing of fractures,[10] pain, necrosis, and weakening of orthopedic implants also happens.[11] Clinical findings and the results from epicutaneous tests[12],[13],[14] are used to diagnose metal allergy. Susceptibility to metal allergy has been shown to have a genetic link,[10] and many patients can have multiple allergies. A history of reaction to metals or jewelry is a risk factor for developing hypersensitization to metal implants.[15] TTherefore, even if the incidence of titanium allergy in the general population is low, patients with a previous history of allergic reactions to metals/jewelry or other significant allergies (e.g., penicillin allergy), a metal allergy assessment and specific allergy tests before placing implants[16] must be done in regular practice.. Epicutaneous tests are the standard procedure to assess Type IV hypersensitivity reactions.[16],[17],[18],[19],[20],[21],[22] The relation between failure of titanium implants and allergy to titanium is complex. Jacobs et al., 1991,[23] and Witt and Swann 1991[24] found that the levels of titanium in the blood of patients having loose titanium hip implants were increased. Subsequently, Frisken et al., 2002,[25] demonstrated a higher concentration of titanium ions in the regional lymph nodes and lungs of animal subjects with failed titanium implants. Elves et al., 1975,[26] found that orthopedic implants which failed without any plausible explanation had a greater incidence of sensitization to metals than the control group which consisted of implants which failed due to known causes. Most of these studies have been done on orthopedic implants. To what extent can these be extrapolated to dental implants is debatable. Dental implants have a limited area of contact between bone and implant. Furthermore, the oral mucosa has less number of antigen-presenting cells (Langerhans cells) than skin. In addition, dental implants in the oral cavity are covered by a pellicle of glycoproteins which decreases their immunologic potential.[16] The prevalence of titanium allergy, though low, has been largely overlooked by profession. Due to its excellent biocompatibility and mechanical properties, the use of titanium, or a material of choice for numerous medical devices, dental and orthopedic rehabilitation is increasing.[27] Therefore, it is important to evaluate the prevalence of titanium hypersensitivity in these patients and to look for alternatives in patients susceptible to titanium allergy. Various materials have been suggested as alternatives. These include zirconia, hydroxyapatite, tantalum, and polyetheretherketone (PEEK).
Materials and Methods | |  |
The research question for this study was to assess whether titanium implants increase the risk for developing titanium hypersensitivity as compared to the general population or not. The electronic search was conducted using the PubMed library of United States National Library of Medicine, Cochrane Central Register of Controlled Trials (CENTRAL) of the Cochrane Collaboration, Ovid, ResearchGate, ScienceDirect, EBSCO, Web of Science, and Google Scholar as online search engines. The keywords used in the search were “Titanium” AND “IMPLANT” AND “HYPERSENSITIVITY” or “ALLERGY.” The references given by the selected articles were also used to find relevant publications. The Contemporary Clinical Dentistry (1997–2015), Journal of Maxillofacial Surgery (1997–2015), and Journal of the American Dental Association (2000–2020) were hand searched for relevant articles. For conducting the meta-analysis, the Review Manager (RevMan) [Computer program]. Version 5.4, The Cochrane Collaboration, 2020. was used.
Criteria for selection of studies
The abstracts of all the publications in our search were screened independently by two reviewers. The articles were shortlisted on the basis of the following inclusion and exclusion criteria. Only case–control studies were selected. Studies with a heterogeneous sample consisting of implant materials other than titanium in the same groups were excluded. Studies with a sample size of <5 were excluded. Studies on both dental and orthopedic implants were selected. Cutaneous and epicutaneous tests for titanium hypersensitivity were used. The relevant data from the selected studies (e.g., study design, methods, and outcome measures) were extracted in duplicate independently by two reviewers.
Statistical analysis
The data from the three studies were divided into two groups. Group I was the test group with patients having titanium implants and thus suspected of having titanium allergy. Group II was the control group and included patients without implants. In each group, the incidence of titanium allergies was recorded. Since the cutaneous and epicutaneous tests used in the three studies were slightly different, the random-effects model was used in the study. The individual effect sizes and odds ratios of the three studies were calculated. The Z-score for the overall effect was calculated. For testing the heterogeneity of the studies, the tau-squared and I-squared tests were conducted. The pooled odds ratios from the studies, with 95% confidence intervals, were obtained through the meta-analysis. Begg and Mazumdar test for publication bias was done. The funnel plot for detecting any publication bias was made with the standard error as the y-axis and the log of the odds ratio as the x-axis.
Results | |  |
Study selection and organization of the data
Through online search engines, 188 titles and abstracts of studies (both case–control and prospective), case reports, and literature reviews on titanium allergy were found [Figure 1]. Out of these, only three case–control studies were found which exclusively studied titanium allergy and could be thus clubbed together in a meta-analysis [Table 1]. | Figure 1: Boolean diagram showing the process of selection of the included studies
Click here to view |
Results of publication bias
Begg and Mazumdar's rank correlation test showed a slight publication bias. The funnel plot for the three studies is shown in [Figure 2].
Meta-analysis
The weighted mean of the odds ratios with 95% confidence intervals showed a strong tendency for patients with titanium implants to have a greater incidence of titanium allergy. However, due to the limited number of studies and the slight publication bias, more research needs to be done on titanium allergy [Figure 3]. | Figure 3: Forest plot showing the relative effect sizes and the pooled effect of the studies
Click here to view |
Discussion | |  |
The massive rise in the use of titanium in various fields has led to an increase in the chance sensitization to titanium through percutaneous and permucosal routes in the general population.[27] To detect titanium hypersensitivity, the patch test has not yet been standardized. A standardized patch test will go a long way in giving a better idea about the prevalence of titanium hypersensitivity in the general population.[28],[29] The exact nature of sensitization to titanium is unknown. Even if titanium is a true sensitizer, it is albeit a weak one. Thomas P et al.[6] showed that the tissue retrieved from a failed titanium hip implant had T-cells and macrophages in the absence of B-cells which suggests Ti allergy. However, Park et al.[30] showed that titanium was not a true dermal sensitizer after local lymph node assay failed to show the signs of titanium allergy. Hosoki et al.[31] described a case of titanium allergy to dental implants where the symptoms (dermatitis and pruritus) were resolved on retrieval of the implants. The prevalence of titanium allergy is probably quite low. It could, however, be the cause of isolated cases of implant failure which cannot be ascribed to any other causes.
Conclusions | |  |
It is, therefore, advisable to test for titanium allergy in patients with a history of multiple and/or severe allergies. These include allergy to artificial jewelry, nickel, cobalt, and penicillin. Furthermore, patients with a previous heavy exposure to titanium (extensive orthopedic, dental rehabilitation with Ti) and those with unexplained implant failure should be tested. Once titanium allergy has been demonstrated in a patient, it is preferable to use alternative treatment modalities or to use alternative materials such as tantalum, PEEK, or zirconia.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References | |  |
1. | Parr GR, Gardner LK, Toth RW. Titanium: The mystery metal of implant dentistry. Dental materials aspects. J Prosthet Dent 1985;54:410-4. |
2. | Abdallah HI, Balsara RK, O'Riordan AC. Pacemaker contact sensitivity: Clinical recognition and management. Ann Thorac Surg 1994;57:1017-8. |
3. | Torgersen S, Gjerdet NR, Erichsen ES, Bang G. Metal particles and tissue changes adjacent to miniplates. A retrieval study. Acta Odontol Scand 1995;53:65-71. |
4. | Haug RH. Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures. J Oral Maxillofac Surg 1996;54:611-7. |
5. | Lalor PA, Revell PA, Gray AB, Wright S, Railton GT, Freeman MA. Sensitivity to titanium. A cause of implant failure? J Bone Joint Surg Br 1991;73:25-8. |
6. | Katou F, Andoh N, Motegi K, Nagura H. Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures. J Craniomaxillofac Surg 1996;24:155-62. |
7. | Lhotka CG, Szekeres T, Fritzer-Szekeres M, Schwarz G, Steffan I, Maschke M, et al. Are allergic reactions to skin clips associated with delayed wound healing? Am J Surg 1998;176:320-3. |
8. | Thomas P, Summer B. Immuno-allergological aspects of adverse reactions in total joint replacement. In: Zippel H, Dietrich M. editors. Bioceramics in Joint Arthroplasty. Ceramics in Orthopaedics. Heidelberg: Steinkopff; 2003. doi: 10.1007/978-3-642-85763-8_11. |
9. | Tamai K, Mitsumori M, Fujishiro S, Kokubo M, Ooya N, Nagata Y, et al. A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 2001;8:90-2. |
10. | Thomas P, Bandl WD, Maier S, Summer B, Przybilla B. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: Case report and review of the literature. Contact Dermatitis 2006;55:199-202. |
11. | Matthew I, Frame JW. Allergic responses to titanium. J Oral Maxillofac Surg 1998;56:1466-7. |
12. | Mitchell DL, Synnott SA, VanDercreek JA. Tissue reaction involving an intraoral skin graft and CP titanium abutments: A clinical report. Int J Oral Maxillofac Implants 1990;5:79-84. |
13. | Bass JK, Fine H, Cisneros GJ. Nickel hypersensitivity in the orthodontic patient. Am J Orthod Dentofacial Orthop 1993;103:280-5. |
14. | Kusy RP. Clinical response to allergies in patients. Am J Orthod Dentofacial Orthop 2004;125:544-7. |
15. | Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 2001;83:428-36. |
16. | Cook SD, McCluskey LC, Martin PC, Haddad RJ Jr. Inflammatory response in retrieved noncemented porous-coated implants. Clin Orthop Relat Res 1991;(264):209-22. |
17. | Vijayaraghavan V, Sabane AV, Tejas K. Hypersensitivity to titanium: A less explored area of research. J Indian Prosthodont Soc 2012;12:201-7. pEpub 2012 Jul 13]. doi: 10.1007/s13191-012-0139-4. |
18. | Ahnlide I, Björkner B, Bruze M, Möller H. Exposure to metallic gold in patients with contact allergy to gold sodium thiosulfate. Contact Dermatitis 2000;43:344-50. doi: 10.1034/j.1600-0536.2000.043006344.x. |
19. | Schramm M. Clinical relevance of allergological tests in total hip replacement. In: Willmann G, editor. Bioceramics in Hip Joint Replacement Proceedings 5th International CeramTec Symposium. 2nd ed. New York, USA: Thieme Publishers; 2017. p. 101-6. |
20. | Yamauchi R, Morita A, Tsuji T. Pacemaker dermatitis from titanium. Contact Dermatitis 2000;42:52-3. |
21. | Bircher AJ, Stern WB. Allergic contact dermatitis from 'titanium' spectacle frames. Contact Dermatitis 2001;45:244-5. |
22. | Suhonen R, Kanerva L. Allergic contact dermatitis caused by palladium on titanium spectacle frames. Contact Dermatitis 2001;44:257-8. doi: 10.1034/j.1600-0536.2001.440409-13.x. |
23. | Jacobs JJ, Skipor AK, Black J, Urban Rm, Galante JO. Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. J Bone Joint Surg Am 1991;73:1475-86. |
24. | Witt JD, Swann M. Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg Br 1991;73:559-63. |
25. | Frisken KW, Dandie GW, Lugowski S, Jordan G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J 2002;47:214-7. |
26. | Elves MW, Wilson JN, Scales JT, Kemp HB. Incidence of metal sensitivity in patients with total joint replacements. Br Med J 1975;4:376-8. |
27. | de Graaf NP, Feilzer AJ, Kleverlaan CJ, Bontkes H, Gibbs S, Rustemeyer T. A retrospective study on titanium sensitivity: Patch test materials and manifestations. Contact Dermatitis 2018;79:85-90. |
28. | Hosoki M, Nishigawa K, Tajima T, Ueda M, Matsuka Y. Cross-sectional observational study exploring clinical risk of titanium allergy caused by dental implants. J Prosthodont Res 2018;62:426-31. |
29. | Sicilia A, Cuesta S, Coma G, Arregui I, Guisasola C, Ruiz E, et al. Titanium allergy in dental implant patients: A clinical study on 1500 consecutive patients. Clin Oral Implants Res 2008;19:823-35. doi: 10.1111/j.1600-0501.2008.01544.x. |
30. | Park YH, Jeong SH, Yi SM, Choi BH, Kim YR, Kim IK, et al. Analysis for the potential of polystyrene and TiO2 nanoparticles to induce skin irritation, phototoxicity, and sensitization. Toxicol In Vitro 2011;25:1863-9. |
31. | Hosoki M, Nishigawa K, Miyamoto Y, Ohe G, Matsuka Y. Allergic contact dermatitis caused by titanium screws and dental implants. J Prosthodont Res 2016;60:213-9. |
[Figure 1], [Figure 2], [Figure 3]
[Table 1]
|