Journal of Pharmacy And Bioallied Sciences
Journal of Pharmacy And Bioallied Sciences Login  | Users Online: 890  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 
    Home | About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions | Online submission


ORIGINAL ARTICLE
Year : 2021  |  Volume : 13  |  Issue : 6  |  Page : 1655-1658

Evaluation of reduction protocols in managing aerosol generation in caries management in COVID 19 in Riyadh: An original research


1 Ministry of Health, Riyadh, Kingdom of Saudi Arabia
2 Medical University of Lodz, Poland, Europe, Poland
3 Department of Oral and Maxillofacial Surgery, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia

Correspondence Address:
Suhael Ahmed
Department of Oral and Maxillofacial Surgery, Riyadh Elm University, Riyadh
Kingdom of Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jpbs.jpbs_390_21

Rights and Permissions

Introduction: External high-volume extraction (HVE) devices may offer a way to reduce any aerosol particulate generated. The aim of this study was to measure the particle count during dental aerosol-generating procedures and compare the results with when a HVE device is used. Materials and Methods: Design A comparative clinical study measuring the amount of PM1, PM2.5, and PM10 aerosol particulate with and without the use of an external HVE device was undertaken. Materials and methods in total, ten restorative procedures were monitored with an industrial Trotec PC220 particle counter. The intervention was an external HVE device. Main outcome methods the air sampler was placed at the average working distance of the clinicians involved in the study − 420 mm. Results: In the present study, aerosol particulate was recorded at statistically significantly increased levels during dental procedures without an external HVE device versus with the device. Discussion The null hypothesis was rejected, in that significant differences were found between the results of the amount of aerosol particle count with and without a HVE device. Conclusion: If the results of the present study are repeated in an in vivo setting, an external high-volume suction device may potentially show a lower risk of transmission of viral particulate.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

suppl
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed374    
    Printed6    
    Emailed0    
    PDF Downloaded42    
    Comments [Add]    

Recommend this journal