Journal of Pharmacy And Bioallied Sciences
Journal of Pharmacy And Bioallied Sciences Login  | Users Online: 303  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size 
    Home | About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions | Online submission


ORIGINAL ARTICLE
Year : 2021  |  Volume : 13  |  Issue : 6  |  Page : 1679-1681

Microleakage at implant abutment and prosthesis interface in cemented implant-supported prosthesis


1 Department of Prosthodontics, Patna Dental College and Hospital, Patna, Bihar, India
2 Department of Prosthodontics, Dr D. Y. Patil Vidyapeeth, Dr. D. Y. Patil Dental College and Hospital, Pimpri, Pune, India, India
3 Department of Community Medicine, GGS Medical College & Hospital, Faridkot, Punjab, India
4 Interns, Christian Dental College, Ludhiana, Punjab, India
5 Department of Oral and Maxillofacial Surgery, Desh Bhagat Dental College, Mandi Gobindgarh, Punjab, India

Correspondence Address:
Vishal Gupta
Department of Community Medicine, GGS Medical College and Hospital, Faridkot, Punjab
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jpbs.jpbs_405_21

Rights and Permissions

Background: Dental implants have an important role in mainstream dental practice today to restore esthetics. The present study was conducted to evaluate the microleakage at implant abutment and prosthesis interface in cemented implant-supported prosthesis. Materials and Methods: The present study comprised sixty replicas of abutment analog with length 5 mm, width of platform 4.8 mm, and taper 6° which were milled and divided into three groups. In Group I, nickel–chromium copings were fabricated; marginal gap was evaluated with optical microscope and luted with zinc oxide noneugenol cement, Group II with zinc polycarboxylate cement, and Group III with zinc phosphate cement. Microleakage was scored by the method used by Tjan et al. Results: The mean microleakage score in Group I was 2.5, in Group II was 1.9, and in Group III was 1.05. The difference was significant (P < 0.05). Conclusion: All cements showed microleakage. Minimum microleakage was seen with zinc phosphate cement than zinc oxide noneugenol cement and zinc polycarboxylate cement.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

suppl
 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed232    
    Printed10    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    

Recommend this journal